HeatScribe 2.1: A Clearer Workspace and More Control Over Your Inspections

HeatScribe 2.1 is here, with a refreshed interface and improvements to image organization, temperature labels, temperature range adjustment, saving and reporting.

HeatScribe is now available for Windows and Apple Silicon Macs.

Some changes are immediately visible: larger text, cleaner thumbnails and simpler dialogs. Others help with the work behind an inspection, such as applying new analysis conditions to several images at once, finding and relinking moved image files and exporting findings to a spreadsheet.

Here’s what’s changed.

A clearer, more readable workspace

The workspace has been updated throughout, with larger text, clearer section headings and more consistent spacing. Fields have a single background colour and smooth rounded outlines, so it’s easier to see where to enter information. Buttons, dropdowns and selection states follow the same styling.

The left panel brings the inspection, library, image groups and findings together. Icons, counts and actions line up more consistently, and long inspection names are shortened to fit, with the full name available on hover. Finding priorities use coloured bars, while image groups keep their coloured dots, with matching dots appearing on image thumbnails in the grid.

Other workspace changes include:

  • Zoom controls at the bottom left of the image and previous/next navigation at the bottom right.

  • Scrollbars that appear when content needs them.

  • A simpler right panel when no thermal image is selected.

  • Clearer disabled buttons and higher-contrast analysis-condition labels.

  • An Import button on the start screen, alongside New Inspection and Open Inspection.

a screenshot of the heatscribe main page

Adjust the thermal display range

Drag the red maximum or blue minimum arrow beside the temperature scale to adjust the thermal display range. The image updates as you drag, so you can see the effect immediately and choose a range that makes the temperature differences you’re examining easier to see.

Choose Auto to restore automatic scaling. Your selected range is saved for that image with the inspection. Changing the colour range doesn’t change the measured temperatures.

a thermal image and its adjustable temperature range

Put temperature labels where you want them

You can now drag a temperature label independently of its measurement point. A leader line keeps the label connected to the measured location, making it easier to position readings around important image detail.

This applies to point readings and the individual readings on area and line measurements. Moving the label leaves the measurement and temperature unchanged. Right-click and choose Reset label position to return to automatic placement.

Optional black backgrounds make readings easier to see over bright or detailed images. The backgrounds can be turned on or off for an individual image or set as a default in Settings.

Label positions and background choices are saved with the inspection and carried into exported images and reports.

a screenshot demonstrating the new temperature labels in heatscribe 2.1

Cleaner thumbnails and easier image organization

Thermal and RGB thumbnails now use consistent, rounded 3:2 previews with a compact filename row. The selection outline surrounds the whole thumbnail, including its filename and group indicator.

If an image has been added to a finding, an icon appears on the top right corner of its thumbnail in the grid (see screenshot below). Gold means the image belongs to a finding; green means it is also included in the report. Hovering over the indicator shows its finding and status.

You can drag individual thumbnails to reorder images in library, group and finding grids. Groups and findings retain their own order. The image order within each finding is also used in the report. Dragging several selected images lets you assign or move them into a group or finding, with destination feedback as you drag.

Selection is more consistent: Command-click toggles individual images, clicking empty grid space clears the selection, and G returns to the grid when you aren’t typing or working in a dialog.


a screenshot showing the new, cleaner UI in HeatScribe 2.1

Edit analysis conditions across selected images

Select several thumbnails and use the Edit Conditions control in the right panel to update their thermal analysis conditions together.

Shared values remain visible, while differing values are marked as Mixed. Only the fields you edit are applied, so you can change emissivity without replacing each image’s other conditions.

"Reset to Defaults" now works across the selected thermal images, clearing their condition and weather overrides and recalculating from the inspection defaults.

thermal images and their thermal parameters

Autosave and a way to reconnect missing images

After you save an inspection for the first time, HeatScribe automatically saves committed changes to that file. New, unnamed work has local recovery copies until its first save.

Recovery is available after an interruption, and through File > Recover Inspection. Recovered work opens as an unsaved inspection so you can review it before saving. Keep your original image files and independent backups alongside your inspection files.

If images move to another folder or drive, Image > Locate Missing Images helps reconnect them without rebuilding findings, groups or measurements.

Export findings to a spreadsheet

The new File > Export findings CSV option creates a findings register you can open in Excel, Numbers or another spreadsheet application.

Choose all findings or only those included in the report. Each finding becomes one row, with columns for inspection details, finding ID and name, priority, asset/location, observation, assessment, next step, notes, image groups and image filenames. Populated finding-specific and custom fields add columns; missing values remain blank.

This is a companion to the PDF report: a practical way to sort findings, track follow-up work or pass a register to a client. It contains finding information and image references, rather than embedded images, individual temperature measurements, GPS coordinates or raw thermal data.

Now available in German

HeatScribe is now available in German, including the app interface, reports and illustrated Quick Start Guide. Choose your preferred language in Settings.

Smaller improvements throughout

This release also includes:

  • A more compact New Inspection wizard

  • Better dialog sizing, scrolling and text wrapping in English and German.

  • More consistent field padding, dropdown corners and template-editor layouts.

  • Clearer measurement selection and crop-tool states.

  • Improvements to trackpad scrolling at the ends of panels and other scroll areas.

  • Finder visibility safeguards for CSV, report, image and finding-sheet exports, including exports to iCloud-backed folders.

  • Fixes for specific Settings and native-menu issues, plus recovery handling for temporary thermal-engine connection failures.

  • Updated English and German Quick Start Guides, available from Help.

Get HeatScribe 2.1

Already own HeatScribe? Download the update

New to HeatScribe? Try it free for 14 days

If you’re already using HeatScribe, this update brings the improvements above into your inspection workflow. If you’re currently trying it, the new version gives you a chance to explore the updated workspace and reporting tools during your trial. Feature availability follows your licence.

As always, I’d like to hear what’s working well and what could be better.